Pick out the wrong statement ?

A. Different solids have different equilibrium moisture curves
B. Total condenser or reboiler is considered equivalent to one theoretical plate in McCabe-Thiele
C. Heat removal load on cooler remains constant, even with increase of the reflux ratio in a
D. Even a forced draft cooling tower cannot cool water below the wet bulb temperature
Correct Option: C. Heat removal load on cooler remains constant, even with increase of the reflux ratio in adistillation column